[2010-03-08] LAP-A_Standard_V3.08 Publish

New Functions 1. Software Version Information Display The software will open a small window after activating the software, and the window will display the current version of the software, the new functions and the modification status. It is convenient for users to learn the current version information of the software. Users can also decide whether to display this window next time. 2. Navigator for Waveform As there is larger waveform data, this function is required for quickly searching or tracing some data. Users can view the position of the current displayed waveform area relative to the whole waveform according to the Navigator window. They can also find the appointed waveform quickly according to the Navigator window. 3. Analog Waveform The Analog Waveform means that the Display Mode of Bus data is not the pure Data Mode, while it displays data change with the curve which looks like a waveform, which, in fact, is a curve to describe the data change. So it is called the Analog Waveform. And also there are two display modes, Single Analog Display and Mixed Analog Display. Single Analog Display: It displays only the Analog Waveform, and the waveform of the four selected sub-channels is not displayed. Mixed Analog Display: It displays not only the Analog Waveform, but also the waveform of the four selected sub-channels. 4. Reverse for Waveform The function of Reverse is used to reverse the captured signal. For example, the high level is changed into low level, and the low level is changed into high level. At the same time, the result of the Reverse is displayed with the broken line. 5. Find Pulse Width The function is mainly used for finding the pulse width in a single channel and the single channel of a Bus. The desired channel can be selected in the Signal Name column; the width value can be entered in the (Min/Max) Pulse Width column according to the Sampling Site Display or Time Display which is selected in the program. 6. Pulse Width Trigger Module The Pulse Width Trigger Module is the peripheral device which is suitable for the LAP-A Series Modules. The Logic Analyzer can set the Pulse Width as the Trigger Condition. All the LAP-A Series Modules can support the function of the Pulse Width Trigger Module. But it is necessary to register before using this function. 7. Chain-Data-Find When activating the function of the Chain-Data-Find, users can input some consecutive data of a Bus, and these data can be comparted by the comma. The software will start the Chain-Data-Find for the consecutive data according to the inputted data. 8. Bus Width Filter When we capture the signal, some noises will appear because of Sampling Frequency or Hardware, ect. In order to avoid influencing the analysis of the Bus data, we use the function of Bus Width Filter to filter the noises. 9. Memory Analyzer The function of Memory Analyzer is used to divide the packet formats in the protocol analyzer and display the Address and Data in an independent list which is better for learning the corresponding relations and status between the Address and Data in the communication of protocol analyzers. Moreover, when users use this function, they can learn its operation, which can improve the efficiency of learning the status. 10. Multi-stacked Logic Analyzer Settings Multi-stacked Logic Analyzer Settings means that many logic analyzers with the same type can adopt some method to connect with the hardware, and the independent logic analyzers are stacked to work by the software, which reinforces the analytic function of the logic analyzer. The number of stacking the Logic Analyzers is “4” at present. It mainly functions in two aspects, such as increasing the RAM Size and the number of the test channels. (This function is available for the LAP-32128U-A, LAP-321000U-A and LAP-322000U-A Modules, and it is not available for the LAP-16032U, LAP-16064U and LAP-16128U Modules.) 11. Support the Wide-screen Display and Double-screen Display Wide-screen Display: The resolution of the displayer is above 1024*768. When the Display Width of the waveform becomes wider, the number of the displayed Waveform is fixed in the former Version. But in the V3.08 Software, the number of the displayed Waveform will be automatically adjusted according to the Display Width of the Screen. Double-screen Display: The V3.08 Software can support the Double-screen Display with which the software can display more waveforms. 12. Support the SDK for the Data Contrast “Open the SDK for the Data Contrast”, it means that our Logic Analyzer Software has the function of the Data Contrast and we provide the SDK for users modifying the function of the Data Contrast according to their requirements; the Data Contrast Interface which is designed by users will be supported by the main program. 13. Support the SDK for the Protocol Analyzer “SDK for the Protocol Analyzer”, it means we open the SDK for the Protocol Analyzer in our LAP-A Software; users can develop the Protocol Analyzer according to their requirements. The SDK of the LAP-A Software will be issued independently. 14. Open the file of LAP-C Series The LAP-16032U Module can open the file of the LAP-C(16032) Module; the LAP-16064U Module can open the file of the LAP-C(16064) Module; LAP-16128U can open the file of the LAP-C(16128) Module; LAP-32128U-A Module can open the file of the LAP-C(32128) Module; the LAP-321000U-A Module can open the file of the LAP-C(321000) Module; the LAP-322000U-A Module can open the file of the LAP-C(322000) Module. Enhanced Functions 1. Add a Default Button in the Dialog Box of the Bus Data Color There is a Default Button added in the Bus Data Color dialog box; it is convenient for users to restore the setting value to the default. 2. Modify the Position of Some Buttons For the convenience of users, the Zoom Out/ Zoom In buttons of Zoom, and the Up/ Next buttons of RAM Size, Internal Clock and Trigger Position, which are located on the both sides of them, are all moved to the same side (right). 3. Add the Prompting Information of the Shortcut Keys in the Tooltips of the Tool Bar The prompting information of the shortcut keys has been added in the Tooltips of the Tool Bar. For example, the prompting information of the New button is “New (Ctrl+N)”. “Ctrl+N” is the Shortcut Key of the function of New. So the added information is convenient for users to know the shortcut keys of the functions. 4. Add a Range Display of the Waveform Display Area in the Information Bar There has been added the Display Range in the Information Bar, and the Trigger Pos in the Information Bar has been deleted. Because the Trigger Pos is always “0”, it is not significant for the display of Trigger Pos. Therefore, we replace the Trigger Pos with the Display Range. 5. Improve the Function of Print The function of Print has been improved so that users can select the pages which they want to print or only the Current Page. 6. Optimize the Function of Packet List As the relative function of the main program is required to be extended, it is necessary to enhance the whole use efficiency of the Logic Analyzer. And the enhanced function can improve the whole value of the Logic Analyzer. Now the function of Packet List can be optimized in six aspects; the details are listed as below. (1) The Packet List Window Supports the Display of the Toolbar of the Protocol Analyzer The Packet List Window can support the display of the Toolbar of the Protocol Analyzer. The Toolbar is provided by the DLL of Protocol Analyzer; the main program provides the Function Interface and Operating Interface. When the main program detects the Toolbar of Protocol Analyzer, the Toolbar will be created and displayed on the Packet List Window. The Toolbar is different for each Protocol Analyzer, but it provides the same function. (2) Support the Display of the Second-order Decoding of the Protocol Analyzer The Toolbar provides the operating window for Second-order Decoding of the Protocol Analyzer. When users activate the function of the Second-order Decoding of the Protocol Analyzer, the Protocol Analyzer will carry out the function of the Second-order Decoding; the data of the packet and waveform will be refreshed according to the results of the Second-order Decoding. The Second-order Decoding is different for each Protocol Analyzer; it can be realized by the function which is provided by the Protocol Analyzer. (3) Support the Display of the Toolbar of the Packet Format Filter This function is convenient for users to detect the change of the appointed packet. The Protocol Analyzer supplies the Toolbar which is the operating window of the Packet Format Filter. The Packet Format Filter of each Protocol Analyzer is different, and it can be realized by the function of the Protocol Analyzer. The Packet List Window can only support the display of the Toolbar of the Packet Format Filter. (4) Users can Set the Display of the Packet#, Name and TimeStamp The display of the Packet#, Name and TimeStamp on the Packet List can be decided by users so that the Packet List Window can be used sufficiently. The Packet List can display these items according to the setting. (5) Support the Display of Data Merge If there are several continuous (8Bit) data in the Packet, the Packet List won’t display several units each of which consists of 8Bit data; it will display all the data as a group. (6) Display the Serial Number If there are several continuous (8Bit) data appearing in the Packet List and the Waveform, the Tooltip is used to display the Serial Number of the data when moving the cursor onto it, and each group of data is 8Bit; it is convenient for users to know the position of the data. 7. Support more new Languages The software will add other new languages in the V3.08 besides the Chinese Simplified (Si), Chinese Traditional (Tr) and English. And the new languages will be issued by way of the independent Installation File. When users install the program of other new language, the software will inspect the program automatically and supply the language for users to switch. 8. Open the Function of Protocol Analyzer Trigger for all the LAP-A Series Modules All the LAP-A Series Modules can use the function of the Protocol Analyzer Trigger. However, LAP-16032U, LAP-16064U, LAP-16128U, LAP-32128U-A, LAP-321000U-A must register before using this function. For the LAP-322000U-A, it is not necessary to register as it can use this function for free. 9. Support the User-defined Data Format of the Protocol Analyzer The Main Program can support the user-defined Data Format of the Protocol Analyzer. That is to say, users can set the Data Format in the Protocol Analyzer according to their requirements so that the Data Format of the Protocol Analyzer can’t be controlled by the settings of Data Format in the Main Program. Modified Functions 1. Modify some Chinese and English words: a) The Enable has been changed into Signal Filter. b) The Customize has been changed into Common Setup and the relative words have been modified. c) The Properties has been changed into Trigger Property. d) The General Bus has been changed into Bus. e) The Chinese of the Protocol Analyzer has been changed. f) The Show As, Character Model and Edit Base Mode have been changed into Data Format. 2. The function of Show Time of Waveform under the Frequency Display cannot take effect. Before Modification: The function of Show Time of Waveform cannot take effect under the Frequency Display. After Modification: The function of Show Time of Waveform can be used normally. 3. In the Double Mode, when the Trigger Position is 100%, there is an error in the Trigger Point, T Bar. Before Modification: The T Bar is not in the correct position; there is an error. After Modification: The T Bar has been in the correct position. 4. It cannot take effect when setting the function, “Read the Captured Data”, in the Customize dialog box; it is necessary to press the Restore Defaults button to enable this function. Before Modification: The function, “Read the Captured Data”, cannot be enabled until the Restore Defaults button in the Customize dialog box is pressed. After Modification: The function, “Read the Captured Data”, can be used. 5. Select the option, “Keep the Present Data” in the Customize dialog box, and then repeatedly trigger and save; press the Stop to close the current file, and then open it again; the unknow data is wrong in the file. Before Modification: When the RAM Size is lower than 64K, repeatedly trigger and save; press the Stop to close the current file, and then open it again; the unknow data is wrong in the file. After Modification: When the RAM Size is lower than 64K, repeatedly trigger and save; press the Stop to close the current file, and then open it again, the unknow data is correct in the file. PS: The software only supports 2000/XP/Vista32/Windows 7(32-Bit) systems at present. LAP-16032U_Standard_V3.08 for 2000、XP、Vista32、Windows 7 【DOWNLOAD】 LAP-16064U_Standard_V3.08 for 2000、XP、Vista32、Windows 7 【DOWNLOAD】 LAP-16128U_Standard_V3.08 for 2000、XP、Vista32、Windows 7 【DOWNLOAD】 LAP-32128U-A_Standard_V3.08 for 2000、XP、Vista32、Windows 7 【DOWNLOAD】 LAP-321000U-A_Standard_V3.08 for 2000、XP、Vista32、Windows 7 【DOWNLOAD】 LAP-322000U-A_Standard_V3.08 for 2000、XP、Vista32、Windows 7 【DOWNLOAD】

 
Copyright ZEROPLUS TECHNOLOGY CO., LTD.