New Funtions 1.The Zoom In and Out Display of the Waveform Window (The Function of Navigator for Waveform ) This function is mainly for keeping pace with the waveform in the selected area of the Navigator. When users move the waveform and some data has been changed, the Navigator will do the corresponding change. 2.The Function of Bus Width Filte When we capture the signal, some noises will appear because of Sampling Frequency or Hardware, ect. In order to avoid influencing the analysis of the Bus Data, we use the function of Bus Width Filter to filter the noises. Fortified Functions 1.Support the Custom Function of the Data Format Display of the Protocol Analyzer Users can customize the relative Data Format according the Data Format od the Protocol Analyzer, which can't be controlled by the Data Format Switch of the Main Program. 2.The Function of Packet Optimization The relative function of the main program is required to be extended, it is necessary to enhance the whole use efficiency of the Logic Analyzer; the added function can be used in the use interface of the Logic Analyzer in order that it can improve the whole value. And it can be divided into six parts, see as below: (1)The Packet List Window supports the Toolbar of the Protocol Analyzer The Packet List Window can support the Toolbar of the Protocol Analyzer, the Toolbar of the Protocol Analyzer is provided by the DLL of Protocol Analyzer; the main program provides the Function Interface and Operating Interface,when it detects the Toolbar of Protocol Analyzer , it will create and display it in the Packet List Window. The Toolbar is different for each Protocol Analyzer, but it provides the same function; the Toolbar can be customized in the Protocol Analyzer according to the condition of Protocol Analyzer. (2) Support the Display of the Second-order Decoding of the Protocol Analyzer The Second-order Decoding of the Protocol Analyzer means providing the operating window though the Toolbar. When users activate the function of the Second-order Decoding of the Protocol Analyzer, the Protocol Analyzer will carry out the function of the Second-order Decoding; the data of the packet and waveform will be refreshed according to the results of the Second-order Decoding. The Second-order Decoding is different for each Protocol Analyzer, it can be realized by the function which is provided by the Protocol Analyzer. The results of the Second-order Decoding can be displayed in Packet List Window. (3) Support the Display of the Packet Format Filter This function is convenient for users to detect the change of the appointed packet. The operating window of the Packet Filter is supplied by the Protocol Analyzer. The Packet Format Filter of each Protocol Analyzer is different, it can be realized by the function of the Protocol Analyzer. The Packet List can only support the Display of the Packet Format Filter. (4)Support the Filter Display of the Packet#, Name and TimeStamp The Display of the Packet#, Name and TimeStamp of the Packet List can be decided by users, so that the Packet List Window can be used sufficiently. The Packet List can display the Data Format according to the result of the Filter. (5)Support the Display of Data Merge If the continuous several (8Bit) data appears in the Packet List, it won’t use the 8Bit(A group) as a unit. Literally speaking it will take all the Data as a group to display. (6) Display the Serial Number If the continuous several (8Bit)Data appears in the Packet List and the Waveform. We will use the mode of the tooltip and take the 8Bit as a basic unit to display the Serial Number of the Data; so that it is convenient for users to set the Data. 3.The Function of Analog Waveform The function of Analog Waveform means that the Display Mode of Bus Data is not the Pure Data Mode, while it displays data change with the curve which looks like a waveform, which, in fact, is a curve to describe the data change. So it is called the Analog Waveform. And also we add two options, Single Analog Display and Mixed Analog Display on the basis of the original Analog Waveform. Single Analog Display: It only displays the Analog Waveform, the waveform of the used four sub-channels can’t be displayed. Mixed Analog Display: It uses the original Display Mode to display the Analog Waveform, and it also can display the waveform of the used four sub-channels. 4.The Function of Adding the Default Button in the Dialog Box of the Bus Data Color In the Bus Data Color Dialog Box, when users find that the setting parameters are unsuitable or they only need the default value to return the defaulted state after they set the parameters, then they can click the Default Button to revert to the default values. The original dialog box hasn’t this button, so users need to close this dialog box to open it again; then it will restore the default. It is inconvenient for users to use, so we add this button in this dialog box. 5.The Function of Modifying the Position of Button We set up the Up/Next Buttons of the Sampling Frequency, Trigger Position, RAM Size, Zoom and Internal Clock in the same side (right), so it is convenient for users to operate. 6.The Function of Adding the Prompting Information of the Shortcut Keys in the Tooltip of the Tool Bar This function adds the Prompting Information of the Shortcut Keys in the Tooltip of the Tool Bar of the LA. For example, the prompting information of the New Button is “New (Ctrl+N)”, the Ctrl+N is the Shortcut Key of the New Function. Then it is convenient for users to understand the use of the Shortcut Keys quickly. 7.The Function of Adding Display Range in the Information Area Add the Display Range of the waveform time in the Data Display Area, the Trigger Position in the information Area is deleted. Because the Trigger Position is always as“0”, there is not meaning for the Data Display; then we modify the Trigger Position as the Display Range. 8.The Function of Full Print This function is mainly convenient for users to select the printing page, meanwhile, users can select to print all the waveforms. Modification Functions 1.The frequency of the Time Mode can’t be displayed. Before Modification: The Frequency Display can’t display the time of waveform. After Modification: The time of waveform can be dispalyed normally. 2.The range of the Pulse Width Before Modification: The max. range of the Find Pulse-width is error; when the Find Pulse-width dialog box is opened and the Sampling Display switches to the Time Display, the max. and min. values don’t update as the Time Display. After Modification: The max. value is 65535 clock. When switching to the Time Display, the max. and min. values can update as the Time Display. 3. The Sampling Frequency can’t be changed by manual. Before Modification: The value of the Sampling Frequency can be inputted by the keyboard. After Modification: It only can use the Menu option. LAP-C(16032)_Standard_V3.07 for 2000、XP、Vista32 【DOWNLOAD】 for Vista64 【DOWNLOAD】 LAP-C(16064)_Standard_V3.07 for 2000、XP、Vista32 【DOWNLOAD】 for Vista64 【DOWNLOAD】 LAP-C(16128)_Standard_V3.07 for 2000、XP、Vista32 【DOWNLOAD】 for Vista64 【DOWNLOAD】 LAP-C(162000)_Standard_V3.07 for 2000、XP、Vista32 【DOWNLOAD】 for Vista64 【DOWNLOAD】 LAP-C(32128)_Standard_V3.07 for 2000、XP、Vista32 【DOWNLOAD】 for Vista64 【DOWNLOAD】 LAP-C(321000)_Standard_V3.07 for 2000、XP、Vista32 【DOWNLOAD】 for Vista64 【DOWNLOAD】 LAP-C(322000)_Standard_V3.07 for 2000、XP、Vista32 【DOWNLOAD】 for Vista64 【DOWNLOAD】