I2C Protocol Analysis
Step 1: Double click icon of LAP-32128U-A_STD to run the software
Step 2: Click “OK” to load the last file used or click “Cancel” to create a new file capturing data from the window of Logic Analyzer appears.
Step 3: When software interface appears, please follow setup process below:
1. Go to setup “RAM size” which 2K、16K、32K、64K、128K are provided. User could select the RAM size meeting requirement. We are selecting 128K here.
2. Go to setup suitable “sample rate” which should be setup at least four times higher then the frequency of the Oscillator on the device under test. In this case the frequency is 12MHz, 12MHz*4=48 MHz, then select 50MHz as sample rate here.
3. Go to setup trigger position at 10% to view the data before triggering.
Step 4:
Go to click channel setup
icon,
the window of channels setup will appear. Please follow the processes below to
setup and rename the channels.
1. Go to click “Delete All” to clearing up all channels.
2. Go to click “Add Bus/Signal” twice getting “New0” and “New1” channels.
3. Highlight “Port A0” to set “New1” cannel, Highlight “Port A1” to set “New0” channels.
4. Go to re-name “New0” into “SCK” and go to re-name “New1” into “SDA”
Step 5: Go to setup the trigger condition as falling edge for the I2C signal.
Step 6: Go to click
the Single Run
icon
to turn on the logic analyzer capturing the data, then turn on the tested
device. The logic analyzer is going to capture and calculate signals. As soon as
the data has been stored in RAM, then system displays the wave.
Step
7: When the system completes the wave display, then go to click
to
show all data which is displayed at better way to be looked.
Step
8: Go to click the I2C
icon,
the window of SPECIAL BUS IIC SETUP is displayed to setup I2C
conditions.
1. Go to click pull down menu of “SDA” and select SDA from the list as “SDA” signal.
2. Go to click pull down menu of “SCL” and select SCK from the list as “SCL” signal.
3. Go to click “Customize”, the window of customize setup will appear for you to set your I2C condition required, then click “OK” to go back to the window of SPECIAL BUS IIC SETUP.
4. Go to click “start” then click “OK” to decode I2C protocol, when all conditions are set.
Step
9: Go to click “Place T bar to the center”
icon,
the trigger point of the I2C wave decoded are shifted to the center of screen.
Step
10: Go to click Zoom in
icon,
the adjust the wave into the better ratio to view.
Step 11: Go to click the roll to shift and view the wave.