I2C Protocol Analysis

Step 1: Double click icon of LAP-32128U-A_STD to run the software

Step 2: Click “OK” to load the last file used or click “Cancel” to create a new file capturing data from the window of Logic Analyzer appears.

Step 3: When software interface appears, please follow setup process below:

1.      Go to setup “RAM size” which 2K16K32K64K128K are provided. User could select the RAM size meeting requirement. We are selecting 128K here.

2.      Go to setup suitable “sample rate” which should be setup at least four times higher then the frequency of the Oscillator on the device under test. In this case the frequency is 12MHz, 12MHz*4=48 MHz, then select 50MHz as sample rate here.

3.  Go to setup trigger position at 10% to view the data before triggering.

Step 4: Go to click channel setup  icon, the window of channels setup will appear. Please follow the processes below to setup and rename the channels.

1.        Go to click “Delete All” to clearing up all channels.

2.        Go to click “Add Bus/Signal” twice getting “New0” and “New1” channels.

3.        Highlight “Port A0” to set “New1” cannel, Highlight “Port A1” to set “New0” channels.

4.        Go to re-name “New0” into “SCK” and go to re-name “New1” into “SDA”

Step 5: Go to setup the trigger condition as falling edge for the I2C signal.

Step 6: Go to click the Single Run  icon to turn on the logic analyzer capturing the data, then turn on the tested device. The logic analyzer is going to capture and calculate signals. As soon as the data has been stored in RAM, then system displays the wave.

Step 7: When the system completes the wave display, then go to click  to show all data which is displayed at better way to be looked.

Step 8: Go to click the I2C  icon, the window of SPECIAL BUS IIC SETUP is displayed to setup I2C conditions.

1.      Go to click pull down menu of “SDA” and select SDA from the list as “SDA” signal.

2.      Go to click pull down menu of “SCL” and select SCK from the list as “SCL” signal.

3.      Go to click “Customize”, the window of customize setup will appear for you to set your I2C  condition required, then click “OK” to go back to the window of SPECIAL BUS IIC SETUP.

4.      Go to click “start” then click “OK” to decode I2C protocol, when all conditions are set.

Step 9: Go to click “Place T bar to the center” icon, the trigger point of the I2C wave decoded are shifted to the center of screen.

Step 10: Go to click Zoom in  icon, the adjust the wave into the better ratio to view.

Step 11: Go to click the roll to shift and view the wave.