[2014-03-05] LAP-B V3.13.02 Release

Modified items 1. Under LSMC 70 mode, using External Trigger would cause the Trigger Bar having a deviation of one sampling point. Before modified: Under LSMC 70 mode, using External Trigger would cause the Trigger Bar having a deviation of one sampling point. After modified: Under LSMC 70 mode, using External Trigger has no effect on the Trigger Bar. 2. In the MEMFOLD page, if the trigger condition is set to edge trigger and level comparison, the Trigger Bar marking would have some problem. Before modified: In the MEMFOLD page, if the trigger condition is set to edge trigger and level comparison, the Trigger Bar marking would have some problem. After modified: In the MEMFOLD page, if the trigger condition is set to edge trigger and level comparison, the Trigger Bar marking has no problem. 3. Above 200MHz, multi-trigger still could be set, and that would cause problem. Before modified: Above 200MHz, multi-trigger still could be set, and that would cause problem. After modified: Above 200MHz(not included), multi-trigger is closed, only single trigger could be set. 4. Under 333MHz, Trigger Count (trigger setting) could be set to not be 1, that would cause problem. Before modified: Under 333MHz, Trigger Count (trigger setting) could be set to not be 1, that would cause problem. After modified: Under 333MHz, Trigger Count (trigger setting) must be set to 1. 5. Above 200MHz, there isn't the prompt 'The trigger level could only be Level 0'. V3.12.02 has it but V3.13.01 removes it. Before modified: Above 200MHz, there isn't the prompt 'The trigger level could only be Level 0'. After modified: Above 200MHz, the prompt 'The trigger level could only be Level 0' is added. 6. Multi-level UI can only set 16 levels, but for LAP-B(702000R) which has 256 levels, it only can set 6 levels, not conform to the actual specification. Before modified: Multi-level UI of LAP-B(705000R) can only set 6 levels, not conform to the actual specification. After modified: Multi-level UI can set 256 levels for LAP-B(702000R), and 16 levels for other devices. 7. Hardware switch is unavailable when V3.13.01 connecting with LAP-B(702000X). Before modified: Hardware switch is unavailable when V3.13.01 connecting with LAP-B(702000X). After modified: Hardware switch is available when V3.13.01 connecting with LAP-B(702000X). 8. Packet list export doesn't support exporting only one file. Before modified: Packet list export doesn't support exporting only one file. After modified: Packet list export supports exporting only one file. 9. The filtering time of Bus width filter is too long. Before modified: The filtering time of Bus width filter is too long. After modified: The filtering efficiency of Bus width filter is improved. 10. The program would show no data (just like opening a new file) if we double click a renamed LA file. Before modified: Double clicking a renamed LA file can't open it. After modified: Double clicking a renamed LA file can open it. 11. In the Traditional Chinese interface of data contrast, there are two 'Previous' buttons. Before modified: In the Traditional Chinese interface of data contrast, there are two 'Previous' buttons. After modified: One 'Previous' button is changed to 'Next' button. 12. Prompt for undating appears in the latest software. Before modified: Prompt for undating appears in the latest software. After modified: Prompt for undating would not appear in the latest software. 13. Under some mode and frequency, function switching is abnormal. Before modified: Function switching is abnormal. After modified: Function switching is normal. 14. Under 6-fold mode, false triggering would happen for some low frequency signal. Before modified: Under 6-fold mode, false triggering would happen for some low frequency signal. After modified: Under 6-fold mode, some trigger settings of low frequency signal are prohibited to prevent from false triggering. LAP-B(702000X) 【DOWNLOAD】 LAP-B(702000R) 【DOWNLOAD】 Discontinued Models LAP-B(702000) 【DOWNLOAD】 LAP-B(702000Z) 【DOWNLOAD】 LAP-B(702000L) 【DOWNLOAD】 LAP-B(702000+) 【DOWNLOAD】 LAP-B(70256) 【DOWNLOAD】 LAP-B(70256L) 【DOWNLOAD】

【 Specifications 】 more ~

 
Copyright ZEROPLUS TECHNOLOGY CO., LTD.